CAPACITY & SIZE SELECTION TABLE
COUNTING WEIGHING SCALE
(PLATFORM SIZE 350 X 240MM)
Model No Capacity Accuracy
UTPC 101 10 kg 1 g
UTPC 202 20 kg 2 g
UTPC 305 30 kg 5 g
 
FEATURES
M.S. powder coated body Suitable for industrial application
Big weighing stainless steel plate size of 350 X 240 mm
21 keys dome key for price sores & recall
3 displays set : 1) gross/net weight display. 2) Price per kg display. 3) Rupees as per weight display
Front, back or front, pole or front. extra display option available
 
AREAS OF USE
General Store ∞ Parcels∞ Freight ∞ Engineering ∞ General Weighing ∞ Shop scale ∞ Retail counter ∞ Sweet Shop ∞ Chicken Shop
 
TECHNICAL SPECIFICATIONS
RATED CAPACITY(RC) : AS PER ABOVE LIST
ACCURACY
: ±1 0.02% RC
NON-LINEARITY
: ±1 0.02 % RC
HYSTERISIS
: +/- 0.03% OFAPPLIED LOAD
NUMBER OF SCALE DIVISION
: 10000 MAX
RESOLUTION
: AS PER ABOVE LIST
TARE PROVISION
: 100% RC
TOLERANCE ON OPREATING VOLTAGE : -20 TO +10" OF OPERATING VOLTAGE
DISPLAY
: RED SEVEN SEGMENT
OVERLOAD INDICATION
: "HELP"
RESPONSE TO FULL SCALE
: 3 SEC
WEIGHT
: AS PER SIZE OF SCALE
DIMENSIONS
: AS PER ABOVE LIST
OPERATING VOLTAGE & FREOUENCY
: 230AC 50HZ
OPERATING TEMPERATURE
: O°C T0 45°C
DRIFT OF NO LOAD O/P WITH TEMERATURE : ± 0.03 % RC
DRIFTOF NO-LOAD OUTPUT WITH TIMEAFTER 1 HRS. : ± 0.05 % RC
DRIFT OF FULL SCALE O/P WITH TIME AFTER 1 HRS. : ± O.05 % RC.
SPEED OF MEASURMENT
: 500 MSEC
ENVIRONMENTAL CONDITION
: NORMAL
CREEP AT 20 MINUTES
: +/- 0.05 % OF APPLIED LOAD
MATERIAL OF CONSTRUCTION
: M.S. steel & pan of 5 .5. sleell
APPROVAL : Weights & measure Dept-Maharashtra & Regional standard laboratory-Ahmedabad
 
COMMON FEATURES
» Software calibration
» Auto zero tracking
» Inbuilt spike guard to protect machine from voltage fluctuations
» "Help" indication on display to indicate over loading. It enhances life of machine Approved from Weight & Measurement Department
» Advance technology integrated microcontroller base circuit with high internal resolution of 21akh counts for better result
» Moisture protection on sensitive circuits
» Fast digital indication with stable reading indication
» In built counting, set point & auto calibration feature
» One programmable conversion facility
» Best quality OIML approved load cells (make MAXLOAD Canada).
» Protection class IP65 of load cell
» Bright red seven segment display of 12mm height
» 150 % over load protection
     
 
OPTIONS AVAILABLE
  • RS 232 COMPUTER INTERFACE WITH COMPUTER SOFTWARE TO PICK UP DATA FROM TEXT FILE
  • THERMAL PRINTER OUTPUT WITH DATE.TIME & WEIGHT
  • DATA LOGGER WITH 500 NOS.RECORDS OF WEIGHT, DATE, & TIME WITH DATA TRANSFER FACILITY IN MICROSOFT EXCEL SHEET
  • Extra display with wire for monitoring weight from cabin
  • Set point controls with relay output
  • RS 485 MODBUS interface for control form PLC panel
  • 4-20 ma current output for PLC cantors
 
 
      know more....
 
 
 
 
 
 
   
     
     
 
ALL RIGHTS RESERVED UNIQUE INSTRUMENTS © 2010 - 2011 WEBSITE DEVELOPED & MAINTAINED: DIGITAL DESTINATIONS